Direct conversion
Semiconductors make charge.
In a direct-conversion detector the photon's energy creates electron-hole pairs right where it is absorbed. A bias voltage sweeps electrons to the anode pixels and holes to the cathode; the moving charge is the signal. One step - no light, no spreading.
photon → E / W electron-hole pairs → drift in the electric field → pixel electrode → ASIC
Physics
What makes a good direct converter?
High Z, high density
Pb, Bi, Cd, Te, Cs, I absorb X- and gamma-rays in mm, not cm.
Band gap 1.5-2.5 eV
Small enough for many pairs, large enough for low thermal leakage without cooling.
High μτ
Mobility × lifetime ≥ 10⁻³ cm²/V lets charges cross mm-thick crystals.
High resistivity
≥ 10⁹-10¹⁰ Ω·cm keeps dark current and noise low under hundreds of volts.
Lab 1
Absorption of direct converters.
Lab 2
Band gap, pair energy and leakage.
Lab 3
Getting the charge out.
Lab 4
Thickness and resolution.
Perovskites
Lead-bromide perovskites: the newcomers.
CsPbBr₃
All-inorganic, melt-grown
- Bridgman ingots up to 1.5″ diameter; zone refining removes impurities
- 0.79 % FWHM at 662 keV (guard ring), 0.86 % at 1332 keV (ring-drift)
- Hole μτ up to ~10⁻² cm²/V, lifetime up to ~300 µs; W ≈ 5.3 eV
- 2.2 cm thick virtual-Frisch-grid detectors: 1.5-2.2 % at 662 keV
- Planar devices match CZT below 0.5 MeV and beat it above 1 MeV
FAPbBr₃
Hybrid, solution-grown
- Grown from solution below 100 °C - cheap, cm-size crystals
- Surface passivation: 5.7 % → 1.7 % at 662 keV, near-unity charge collection
- Br₂ during growth cuts Br vacancies ~1000× → 0.7 % at 662 keV
- FA/Cs alloy: balanced μτ (2.2-3.2)×10⁻³ cm²/V, ρ ≈ 10¹⁰ Ω·cm
- Photon-counting X-ray: iodine K-edge contrast at low dose
Device engineering
What made the progress
- Asymmetric / Schottky contacts (Ga, Bi | Au, Pt) for low dark current
- Unipolar hole-only readout: pixels, ring-drift, virtual Frisch grid
- Blocking & passivation layers (TiC, Al₂O₃) against polarisation
- Encapsulation (wax, ALD Al₂O₃) for months of stable bias
- X-ray photon counting at ~0.4 Mcps/pixel; Br₂-doped crystals as 350 ps scintillators
| Year | Material / device | Result | Source |
|---|---|---|---|
| 2018 | CsPbBr₃, Bridgman, Ga/Au planar | 3.8 % at 662 keV, 3.9 % at 122 keV; μτ(h) 1.3×10⁻³ cm²/V | He et al., Nat. Commun. 9, 1609 |
| 2021 | CsPbBr₃, 1.5″ ingots, hole-only | 1.4 % at 662 keV; μτ(h) 8×10⁻³ cm²/V; stable 18 months | He et al., Nat. Photon. 15, 36 |
| 2023 | FA₀.₉Cs₀.₁PbBr₃, solution-grown | 2.9 % at 662 keV; >65 % of crystals spectroscopic | Zhao et al., Nat. Photon. 17, 315 |
| 2024 | FAPbBr₃, NH₄Br-passivated surface | 1.7 % at 662 keV; dark counts ↓60×; works >130 °C | Zhao et al., Nat. Photon. 18, 250 |
| 2024 | CsPbBr₃, EFG-grown, X-ray | ρ 1.6×10¹⁰ Ω·cm; 46 180 µC Gy⁻¹cm⁻²; LoD 10.8 nGy/s | Hua et al., Nat. Photon. 18, 870 |
| 2025 | CsPbBr₃, virtual Frisch grid, 2.2 cm | 1.5 % (10 mm) and 2.2 % (22 mm) at 662 keV, digital pulse processing | Qin et al., Nat. Commun. 16, 158 |
| 2025 | FAPbBr₃, Br₂ defect healing | 0.7 % at 662 keV; X-ray photon counting | Li et al., Nat. Mater. 24, 1993 |
| 2025 | CsPbBr₃ planar vs CZT | Better than CZT above 1 MeV; 225 days stable | Bayikadi et al., Adv. Mater. 37, e10931 |
| 2026 | CsPbBr₃, zone-refined Bridgman | 0.79 % at 662 keV; 0.86 % at 1332 keV | Grundmanis et al., NIM A 1084; Crystals 16, 712 |
| 2026 | CsPbBr₃ X-ray photon counting | ~420 kcps/pixel; 2.9 % at 122 keV; K-edge imaging | Bayikadi et al., ACS Energy Lett. 11, 5801 |
Room-temperature, best reported values from each paper.
Open questions
Data
Semiconductor properties.
| Material | Formula | ρ g/cm³ | Z eff | Band gap | W (eV/pair) | Pairs per MeV | Notes |
|---|---|---|---|---|---|---|---|
| Silicon (photodiode) | Si | 2.33 | 14 | 1.12 eV | 3.62 | 276,243 | Excellent for light and soft X-rays; Z = 14 is too light to stop hard X/γ-rays. |
| a-Se | Se | 4.28 | 34 | 2.2 eV | 45 | 22,222 | Direct-conversion mammography panels. W ≈ 45 eV at typical fields. |
| HPGe | Ge | 5.32 | 32 | 0.67 eV | 2.96 | 337,838 | Best energy resolution, but must be cooled to ~77 K. |
| CdTe | CdTe | 5.85 | 50.2 | 1.44 eV | 4.43 | 225,734 | Photon-counting CT and X-ray spectroscopy; room temperature. |
| CdZnTe (CZT) | Cd0.9Zn0.1Te | 5.78 | 49.9 | 1.57 eV | 4.6 | 217,391 | Room-temperature gamma spectroscopy, cardiac SPECT, PCD-CT. |
| CsPbBr₃ | CsPbBr3 | 4.55 | 62.2 | 2.25 eV | 5.3 | 188,679 | All-inorganic halide perovskite: high Z (Pb, Cs), melt-grown (Bridgman, zone-refined) crystals; 0.8-1.4 % FWHM at 662 keV, hole μτ up to ~10⁻² cm²/V, W ≈ 5.3 eV measured. |
| FAPbBr₃ * | CH5N2PbBr3 | 3.8 | 61.4 | 2.25 eV | 6.9 | 144,928 | Formamidinium lead bromide: solution-grown below 100 °C; 0.7 % FWHM at 662 keV after Br₂ defect healing, balanced μτ ≈ 2-3×10⁻³ cm²/V; also photon-counting X-ray (iodine K-edge). |
Z eff: power-law effective atomic number for photo-absorption, computed from the composition. * FAPbBr₃ W-value is an estimate (Klein rule); CsPbBr₃ W ≈ 5.3 eV is measured.
Compare with indirect conversion